
{"id":5522,"date":"2023-05-30T14:21:54","date_gmt":"2023-05-30T18:21:54","guid":{"rendered":"https:\/\/spray-sensors.shany.ca\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/"},"modified":"2023-11-02T15:47:28","modified_gmt":"2023-11-02T19:47:28","slug":"importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying","status":"publish","type":"post","link":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/","title":{"rendered":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying"},"content":{"rendered":"<p>In-flight particle state parameters (PSPs) have been shown to play a crucial role in determining the properties of atmospheric plasma-sprayed coatings. Therefore, PSPs are frequently measured before\u00a0 starting a coating run as part of process control. This paper shows the importance of the measurement procedure used and subsequent data processing applied for the evaluation of PSPs, with the focus on process control applications. The paper demonstrates this on the example of coating of yttria-stabilized zirconia, using a commercially available sensor system Accuraspray-G3C for measuring the ensemble particle temperatures and velocities as descriptors of the PSPs. Experimental results show a longer stabilization time of the particle jet than what is practically considered, revealing the need for an appropriate choice of the measurement procedure. Furthermore, it is demonstrated that information about PSPs can be acquired also during the coating run by periodically moving the coating gun to a stationary sensor system only for a short measurement duration. Lastly, it is shown how different data processing methods affect the evaluation of the acquired PSPs.<\/p>\n<p><a class=\"btn-tec black\" href=\"https:\/\/www.research-collection.ethz.ch\/bitstream\/handle\/20.500.11850\/584655\/2\/s11666-022-01495-w.pdf\" target=\"_blank\" rel=\"noopener\">Link to publication<\/a><\/p>\n<p>Keywords: atmospheric plasma spraying, data processing, in-flight particle diagnostics, particle state parameters, process monitoring, process control<\/p>\n<p><em><small>Originally published at Journal of Thermal Spray Technology (32(2))<br \/>\nBy Hudomalj Uro\u0161, Fallahi Sichani Ehsan, Weiss Lukas, Nabavi Majid, Wegener Konrad<\/small><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In-flight particle state parameters (PSPs) have been shown to play a crucial role in determining the properties of atmospheric plasma-sprayed [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":22,"featured_media":5497,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[54],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray\" \/>\n<meta property=\"og:description\" content=\"In-flight particle state parameters (PSPs) have been shown to play a crucial role in determining the properties of atmospheric plasma-sprayed [...]Read More...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnar Thermal Spray\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnarautomation\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-30T18:21:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-02T19:47:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spray-sensors.shany.ca\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Flavia Fu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Flavia Fu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\"},\"author\":{\"name\":\"Flavia Fu\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\"},\"headline\":\"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying\",\"datePublished\":\"2023-05-30T18:21:54+00:00\",\"dateModified\":\"2023-11-02T19:47:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\"},\"wordCount\":224,\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png\",\"articleSection\":[\"Accuraspray\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\",\"name\":\"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray\",\"isPartOf\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png\",\"datePublished\":\"2023-05-30T18:21:54+00:00\",\"dateModified\":\"2023-11-02T19:47:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/spraysensors.tecnar.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"name\":\"Spray Sensors\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\",\"name\":\"Tecnar Automation Ltd\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"width\":480,\"height\":186,\"caption\":\"Tecnar Automation Ltd\"},\"image\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tecnarautomation\",\"https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray\",\"https:\/\/www.youtube.com\/@tecnarchannel2194\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\",\"name\":\"Flavia Fu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"caption\":\"Flavia Fu\"},\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/","og_locale":"fr_FR","og_type":"article","og_title":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray","og_description":"In-flight particle state parameters (PSPs) have been shown to play a crucial role in determining the properties of atmospheric plasma-sprayed [...]Read More...","og_url":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/","og_site_name":"Tecnar Thermal Spray","article_publisher":"https:\/\/www.facebook.com\/tecnarautomation","article_published_time":"2023-05-30T18:21:54+00:00","article_modified_time":"2023-11-02T19:47:28+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/spray-sensors.shany.ca\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png","type":"image\/png"}],"author":"Flavia Fu","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Flavia Fu","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#article","isPartOf":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/"},"author":{"name":"Flavia Fu","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f"},"headline":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying","datePublished":"2023-05-30T18:21:54+00:00","dateModified":"2023-11-02T19:47:28+00:00","mainEntityOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/"},"wordCount":224,"publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png","articleSection":["Accuraspray"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/","url":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/","name":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying - Tecnar Thermal Spray","isPartOf":{"@id":"https:\/\/spray-sensors.shany.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png","datePublished":"2023-05-30T18:21:54+00:00","dateModified":"2023-11-02T19:47:28+00:00","breadcrumb":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#primaryimage","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2023\/10\/SpraySensors-800x500-7.png","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/spraysensors.tecnar.com\/fr\/importance-of-measurement-and-evaluation-procedure-of-particle-state-in-atmospheric-plasma-spraying\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spraysensors.tecnar.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Importance of Measurement and Evaluation Procedure of Particle State in Atmospheric Plasma Spraying"}]},{"@type":"WebSite","@id":"https:\/\/spray-sensors.shany.ca\/#website","url":"https:\/\/spray-sensors.shany.ca\/","name":"Spray Sensors","description":"","publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spray-sensors.shany.ca\/#organization","name":"Tecnar Automation Ltd","url":"https:\/\/spray-sensors.shany.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","width":480,"height":186,"caption":"Tecnar Automation Ltd"},"image":{"@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnarautomation","https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray","https:\/\/www.youtube.com\/@tecnarchannel2194"]},{"@type":"Person","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f","name":"Flavia Fu","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","caption":"Flavia Fu"},"url":"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/"}]}},"_links":{"self":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/5522"}],"collection":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/comments?post=5522"}],"version-history":[{"count":1,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/5522\/revisions"}],"predecessor-version":[{"id":5577,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/5522\/revisions\/5577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media\/5497"}],"wp:attachment":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media?parent=5522"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/categories?post=5522"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/tags?post=5522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}