{"id":6175,"date":"2024-02-17T13:55:43","date_gmt":"2024-02-17T18:55:43","guid":{"rendered":"https:\/\/spray-sensors.shany.ca\/?p=6175"},"modified":"2024-09-26T11:50:42","modified_gmt":"2024-09-26T15:50:42","slug":"influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings","status":"publish","type":"post","link":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/","title":{"rendered":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings"},"content":{"rendered":"<p>The electrical and mechanical properties of cold-sprayed coatings dependon the particle size of the feedstock powder, as it greatly influences boththe particle velocity and critical velocity. However, very little has beendone to investigate their influences separately. In this study, two typesof spherical pure copper powders with different particle sizes (i.e., fineand coarse) were employed as feedstock powders for coating production.Two coatings were initially fabricated using these powders under identicalspray conditions, resulting in different particle velocities due totheir distinct particle sizes. An additional coating was produced underadjusted spray conditions, with the fine powder sprayed at a particlevelocity equivalent to that of the previously sprayed coarse powder. Asexpected, at the same spray conditions, finer powders obtain higherparticle velocity than coarser ones, and result in coatings with improvedproperties and microstructures. However, it is also demonstrated that,at the same particle velocities, coarser powders have better as-sprayedproperties and microstructures due to their lower critical velocity<\/p>\n<p><a class=\"btn-tec black\" href=\"https:\/\/ouci.dntb.gov.ua\/en\/works\/7pg8aAB9\/\" target=\"_blank\" rel=\"noopener\">Link to publication<\/a><\/p>\n<p>Key words: Copper, Cold Spray, Feedstock Powder Characteristics, Particle velocity, Mechanical Properties, Electrical Conductivity<\/p>\n<p>By B. Kotsakis Ioannis, Fallah Panteha, Poirier Dominique, Giallonardo Jason D., and Yue Stephen<\/small><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The electrical and mechanical properties of cold-sprayed coatings dependon the particle size of the feedstock powder, as it greatly influences [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":22,"featured_media":6176,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[58],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray\" \/>\n<meta property=\"og:description\" content=\"The electrical and mechanical properties of cold-sprayed coatings dependon the particle size of the feedstock powder, as it greatly influences [...]Read More...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnar Thermal Spray\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnarautomation\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-17T18:55:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-26T15:50:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Flavia Fu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Flavia Fu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\"},\"author\":{\"name\":\"Flavia Fu\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\"},\"headline\":\"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings\",\"datePublished\":\"2024-02-17T18:55:43+00:00\",\"dateModified\":\"2024-09-26T15:50:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\"},\"wordCount\":198,\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png\",\"articleSection\":[\"Coldspray Meter\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\",\"name\":\"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray\",\"isPartOf\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png\",\"datePublished\":\"2024-02-17T18:55:43+00:00\",\"dateModified\":\"2024-09-26T15:50:42+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/spraysensors.tecnar.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"name\":\"Spray Sensors\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\",\"name\":\"Tecnar Automation Ltd\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"width\":480,\"height\":186,\"caption\":\"Tecnar Automation Ltd\"},\"image\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tecnarautomation\",\"https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray\",\"https:\/\/www.youtube.com\/@tecnarchannel2194\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\",\"name\":\"Flavia Fu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"caption\":\"Flavia Fu\"},\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/","og_locale":"fr_FR","og_type":"article","og_title":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray","og_description":"The electrical and mechanical properties of cold-sprayed coatings dependon the particle size of the feedstock powder, as it greatly influences [...]Read More...","og_url":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/","og_site_name":"Tecnar Thermal Spray","article_publisher":"https:\/\/www.facebook.com\/tecnarautomation","article_published_time":"2024-02-17T18:55:43+00:00","article_modified_time":"2024-09-26T15:50:42+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png","type":"image\/png"}],"author":"Flavia Fu","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Flavia Fu","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#article","isPartOf":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/"},"author":{"name":"Flavia Fu","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f"},"headline":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings","datePublished":"2024-02-17T18:55:43+00:00","dateModified":"2024-09-26T15:50:42+00:00","mainEntityOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/"},"wordCount":198,"publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png","articleSection":["Coldspray Meter"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/","url":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/","name":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings - Tecnar Thermal Spray","isPartOf":{"@id":"https:\/\/spray-sensors.shany.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png","datePublished":"2024-02-17T18:55:43+00:00","dateModified":"2024-09-26T15:50:42+00:00","breadcrumb":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#primaryimage","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2024\/07\/SpraySensors-800x500-30.png","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/spraysensors.tecnar.com\/fr\/influence-of-particle-velocity-and-size-on-the-quality-of-cold-sprayed-copper-coatings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spraysensors.tecnar.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Influence of Particle Velocity and Size on the Quality of Cold Sprayed Copper Coatings"}]},{"@type":"WebSite","@id":"https:\/\/spray-sensors.shany.ca\/#website","url":"https:\/\/spray-sensors.shany.ca\/","name":"Spray Sensors","description":"","publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spray-sensors.shany.ca\/#organization","name":"Tecnar Automation Ltd","url":"https:\/\/spray-sensors.shany.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","width":480,"height":186,"caption":"Tecnar Automation Ltd"},"image":{"@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnarautomation","https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray","https:\/\/www.youtube.com\/@tecnarchannel2194"]},{"@type":"Person","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f","name":"Flavia Fu","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","caption":"Flavia Fu"},"url":"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/"}]}},"_links":{"self":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/6175"}],"collection":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/comments?post=6175"}],"version-history":[{"count":3,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/6175\/revisions"}],"predecessor-version":[{"id":6254,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/6175\/revisions\/6254"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media\/6176"}],"wp:attachment":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media?parent=6175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/categories?post=6175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/tags?post=6175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}