
{"id":7108,"date":"2025-04-01T15:55:38","date_gmt":"2025-04-01T19:55:38","guid":{"rendered":"https:\/\/spraysensors.tecnar.com\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/"},"modified":"2025-04-01T15:55:38","modified_gmt":"2025-04-01T19:55:38","slug":"investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment","status":"publish","type":"post","link":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/","title":{"rendered":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment"},"content":{"rendered":"<p>This study investigates the corrosion and erosion-corrosion performance of HVOF-sprayed WC-10Co-4Cr coatings for offshore hydraulic applications. By tuning kerosene (18.1\u201325.3\u2009l\u00b7h\u22121) and oxygen (820\u2013990\u2009l\u00b7min\u22121) flow rates, coatings with optimal hardness (1200 HV0.3), porosity (0.35%), carbide retention (90%), and polarization resistance (15.2\u2009k\u03a9\u00b7cm\u22122) are attained. In-flight diagnostics reveal that particle temperatures and velocities peak at 1,842\u00b0C and 799\u2009m\u00b7s\u22121, respectively, at stoichiometric combustion. Higher temperatures degrade electrochemical stability due to enriched binders when 30% of carbides decompose. The localized attack is mitigated as splatting from high-velocity particles eliminates 25% more porosity. With exposure to sulfate-reducing bacteria for 15 days, polarization resistance reduces to 12.4\u2009k\u03a9\u00b7cm\u22122 owing to biofilm formation, indicating self-healing effects from protective corrosion films. The optimized WC-CoCr coatings reduce corrosion rates under combined erosion and bacterial conditions by 86% compared to untreated steel substrates. This research provides a framework to customize HVOF coatings for demanding offshore conditions.<\/p>\n<p><a class=\"btn-tec black\" href=\"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/rams-2024-0066\/html\" target=\"_blank\" rel=\"noopener\">Link to publication<\/a><\/p>\n<p>Key words:\u00a0HVOF parameters, carbide dissolution, electrochemical impedance, splat adhesion, self-healing oxide<\/p>\n<p><em><small>Originally published at\u00a0Reviews on Advanced Materials Science\u00a0(February 2025)<\/small><\/em><\/p>\n<p>By Zhihui Xing, Na Wang, Lei Fan, Li Shang and Lianzhou Yu<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This study investigates the corrosion and erosion-corrosion performance of HVOF-sprayed WC-10Co-4Cr coatings for offshore hydraulic applications. By tuning kerosene (18.1\u201325.3\u2009l\u00b7h\u22121) [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":22,"featured_media":7106,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[54],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray\" \/>\n<meta property=\"og:description\" content=\"This study investigates the corrosion and erosion-corrosion performance of HVOF-sprayed WC-10Co-4Cr coatings for offshore hydraulic applications. By tuning kerosene (18.1\u201325.3\u2009l\u00b7h\u22121) [...]Read More...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnar Thermal Spray\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnarautomation\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-01T19:55:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Flavia Fu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Flavia Fu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\"},\"author\":{\"name\":\"Flavia Fu\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\"},\"headline\":\"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment\",\"datePublished\":\"2025-04-01T19:55:38+00:00\",\"dateModified\":\"2025-04-01T19:55:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\"},\"wordCount\":194,\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png\",\"articleSection\":[\"Accuraspray\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\",\"name\":\"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray\",\"isPartOf\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png\",\"datePublished\":\"2025-04-01T19:55:38+00:00\",\"dateModified\":\"2025-04-01T19:55:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/spraysensors.tecnar.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"name\":\"Spray Sensors\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\",\"name\":\"Tecnar Automation Ltd\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"width\":480,\"height\":186,\"caption\":\"Tecnar Automation Ltd\"},\"image\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tecnarautomation\",\"https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray\",\"https:\/\/www.youtube.com\/@tecnarchannel2194\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f\",\"name\":\"Flavia Fu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"caption\":\"Flavia Fu\"},\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/","og_locale":"fr_FR","og_type":"article","og_title":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray","og_description":"This study investigates the corrosion and erosion-corrosion performance of HVOF-sprayed WC-10Co-4Cr coatings for offshore hydraulic applications. By tuning kerosene (18.1\u201325.3\u2009l\u00b7h\u22121) [...]Read More...","og_url":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/","og_site_name":"Tecnar Thermal Spray","article_publisher":"https:\/\/www.facebook.com\/tecnarautomation","article_published_time":"2025-04-01T19:55:38+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png","type":"image\/png"}],"author":"Flavia Fu","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Flavia Fu","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#article","isPartOf":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/"},"author":{"name":"Flavia Fu","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f"},"headline":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment","datePublished":"2025-04-01T19:55:38+00:00","dateModified":"2025-04-01T19:55:38+00:00","mainEntityOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/"},"wordCount":194,"publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png","articleSection":["Accuraspray"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/","url":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/","name":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment - Tecnar Thermal Spray","isPartOf":{"@id":"https:\/\/spray-sensors.shany.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png","datePublished":"2025-04-01T19:55:38+00:00","dateModified":"2025-04-01T19:55:38+00:00","breadcrumb":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#primaryimage","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/04\/Website-library-image-1.png","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/spraysensors.tecnar.com\/fr\/investigation-of-the-corrosion-performance-of-hvof-sprayed-wc-cocr-coatings-applied-on-offshore-hydraulic-equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spraysensors.tecnar.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Investigation Of The Corrosion Performance Of HVOF-Sprayed WC-Cocr Coatings Applied On Offshore Hydraulic Equipment"}]},{"@type":"WebSite","@id":"https:\/\/spray-sensors.shany.ca\/#website","url":"https:\/\/spray-sensors.shany.ca\/","name":"Spray Sensors","description":"","publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spray-sensors.shany.ca\/#organization","name":"Tecnar Automation Ltd","url":"https:\/\/spray-sensors.shany.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","width":480,"height":186,"caption":"Tecnar Automation Ltd"},"image":{"@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnarautomation","https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray","https:\/\/www.youtube.com\/@tecnarchannel2194"]},{"@type":"Person","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/34d54d027447e60a3c51e3378480de0f","name":"Flavia Fu","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","caption":"Flavia Fu"},"url":"https:\/\/spraysensors.tecnar.com\/fr\/author\/flavia\/"}]}},"_links":{"self":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/7108"}],"collection":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/comments?post=7108"}],"version-history":[{"count":0,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/7108\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media\/7106"}],"wp:attachment":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media?parent=7108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/categories?post=7108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/tags?post=7108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}