
{"id":7467,"date":"2025-09-22T08:50:12","date_gmt":"2025-09-22T12:50:12","guid":{"rendered":"https:\/\/spraysensors.tecnar.com\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/"},"modified":"2025-09-22T08:50:12","modified_gmt":"2025-09-22T12:50:12","slug":"single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters","status":"publish","type":"post","link":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/","title":{"rendered":"Single-Particle Impact of Ti6Al4V and Ti-5553 in Cold Spray: A Novel Approach to Flattening Ratio and Selecting Johnson\u2013Cook Model Parameters"},"content":{"rendered":"<p>The application of Finite Element Analysis (FEA) in cold spray (CS) provides valuable information about material deformation and stress distribution. The Johnson\u2013Cook (JC)\u00a0model is widely used to simulate material behavior, while the particle Flattening Ratio (FR) is commonly used to assess the deformation pattern and mechanism. FR has also been employed to evaluate and select appropriate JC model parameters. Experimental FR values can be obtained from a cross-sectional view of splats; however, the accuracy of these values can be affected by the sectioning location. This study introduces a novel approach for experimental FR observation by integrating top and cross-sectional views of Ti6Al4V and Ti-5553 deposited particle splats, addressing the limitations of the conventional cross-sectional FR method. The influence of the sectioning region on FR values was systematically evaluated through numerical and experimental analyses. Experimental FR results show that off-axis sectioning leads to overestimating FR values, with increases of 25.98% for Ti6Al4V and 15.45% for Ti-5553. The differences in critical velocities obtained using the FEA between the two FR measurement approaches were approximately 24.61% for Ti6Al4V and 32.46% for Ti-5553. The findings highlight the importance of accuracy in FR measurement and its effect on JC parameter selection and FEA results.<\/p>\n<p><a class=\"btn-tec black\" href=\"https:\/\/link.springer.com\/article\/10.1007\/s11666-025-02063-8\" target=\"_blank\" rel=\"noopener\">Link to publication<\/a><\/p>\n<p><em><small>Originally published in Journal of Thermal Spray Technology, September 17th 2025<br \/>\n<\/small><\/em><\/p>\n<p>A. A\u011f\u0131r, C. J. Akisin, K. Singh, C. J. Bennett &amp; T. Hussain<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The application of Finite Element Analysis (FEA) in cold spray (CS) provides valuable information about material deformation and stress distribution. [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":2,"featured_media":7460,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[69],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Improving Flattening Ratio Accuracy in Cold Spray FEA<\/title>\n<meta name=\"description\" content=\"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Improving Flattening Ratio Accuracy in Cold Spray FEA\" \/>\n<meta property=\"og:description\" content=\"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnar Thermal Spray\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnarautomation\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-22T12:50:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Caroline Moisan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Caroline Moisan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\"},\"author\":{\"name\":\"Caroline Moisan\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/b6fe8d7909fb98ed3882edb1902f9977\"},\"headline\":\"Single-Particle Impact of Ti6Al4V and Ti-5553 in Cold Spray: A Novel Approach to Flattening Ratio and Selecting Johnson\u2013Cook Model Parameters\",\"datePublished\":\"2025-09-22T12:50:12+00:00\",\"dateModified\":\"2025-09-22T12:50:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\"},\"wordCount\":253,\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg\",\"articleSection\":[\"Accuraspray CS\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\",\"name\":\"Improving Flattening Ratio Accuracy in Cold Spray FEA\",\"isPartOf\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg\",\"datePublished\":\"2025-09-22T12:50:12+00:00\",\"dateModified\":\"2025-09-22T12:50:12+00:00\",\"description\":\"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.\",\"breadcrumb\":{\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/spraysensors.tecnar.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single-Particle Impact of Ti6Al4V and Ti-5553 in Cold Spray: A Novel Approach to Flattening Ratio and Selecting Johnson\u2013Cook Model Parameters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#website\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"name\":\"Spray Sensors\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#organization\",\"name\":\"Tecnar Automation Ltd\",\"url\":\"https:\/\/spray-sensors.shany.ca\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"contentUrl\":\"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"width\":480,\"height\":186,\"caption\":\"Tecnar Automation Ltd\"},\"image\":{\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tecnarautomation\",\"https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray\",\"https:\/\/www.youtube.com\/@tecnarchannel2194\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/b6fe8d7909fb98ed3882edb1902f9977\",\"name\":\"Caroline Moisan\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/885a805b5a34762a5d60c83e8b822a78?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/885a805b5a34762a5d60c83e8b822a78?s=96&d=mm&r=g\",\"caption\":\"Caroline Moisan\"},\"url\":\"https:\/\/spraysensors.tecnar.com\/fr\/author\/caroline\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Improving Flattening Ratio Accuracy in Cold Spray FEA","description":"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/","og_locale":"fr_FR","og_type":"article","og_title":"Improving Flattening Ratio Accuracy in Cold Spray FEA","og_description":"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.","og_url":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/","og_site_name":"Tecnar Thermal Spray","article_publisher":"https:\/\/www.facebook.com\/tecnarautomation","article_published_time":"2025-09-22T12:50:12+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg","type":"image\/jpeg"}],"author":"Caroline Moisan","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Caroline Moisan","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#article","isPartOf":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/"},"author":{"name":"Caroline Moisan","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/b6fe8d7909fb98ed3882edb1902f9977"},"headline":"Single-Particle Impact of Ti6Al4V and Ti-5553 in Cold Spray: A Novel Approach to Flattening Ratio and Selecting Johnson\u2013Cook Model Parameters","datePublished":"2025-09-22T12:50:12+00:00","dateModified":"2025-09-22T12:50:12+00:00","mainEntityOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/"},"wordCount":253,"publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg","articleSection":["Accuraspray CS"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/","url":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/","name":"Improving Flattening Ratio Accuracy in Cold Spray FEA","isPartOf":{"@id":"https:\/\/spray-sensors.shany.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage"},"image":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg","datePublished":"2025-09-22T12:50:12+00:00","dateModified":"2025-09-22T12:50:12+00:00","description":"Study introduces a new method to improve Flattening Ratio accuracy in cold spray, enhancing Johnson\u2013Cook modeling and FEA predictions for Ti alloys.","breadcrumb":{"@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#primaryimage","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2025\/09\/Web-SpraySensors-800x500-1.jpg","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/spraysensors.tecnar.com\/fr\/single-particle-impact-of-ti6al4v-and-ti-5553-in-cold-spray-a-novel-approach-to-flattening-ratio-and-selecting-johnson-cook-model-parameters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spraysensors.tecnar.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Single-Particle Impact of Ti6Al4V and Ti-5553 in Cold Spray: A Novel Approach to Flattening Ratio and Selecting Johnson\u2013Cook Model Parameters"}]},{"@type":"WebSite","@id":"https:\/\/spray-sensors.shany.ca\/#website","url":"https:\/\/spray-sensors.shany.ca\/","name":"Spray Sensors","description":"","publisher":{"@id":"https:\/\/spray-sensors.shany.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spray-sensors.shany.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/spray-sensors.shany.ca\/#organization","name":"Tecnar Automation Ltd","url":"https:\/\/spray-sensors.shany.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/","url":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","contentUrl":"https:\/\/spraysensors.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","width":480,"height":186,"caption":"Tecnar Automation Ltd"},"image":{"@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnarautomation","https:\/\/www.linkedin.com\/showcase\/tecnar-thermal-spray","https:\/\/www.youtube.com\/@tecnarchannel2194"]},{"@type":"Person","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/b6fe8d7909fb98ed3882edb1902f9977","name":"Caroline Moisan","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/spray-sensors.shany.ca\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/885a805b5a34762a5d60c83e8b822a78?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/885a805b5a34762a5d60c83e8b822a78?s=96&d=mm&r=g","caption":"Caroline Moisan"},"url":"https:\/\/spraysensors.tecnar.com\/fr\/author\/caroline\/"}]}},"_links":{"self":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/7467"}],"collection":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/comments?post=7467"}],"version-history":[{"count":0,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/posts\/7467\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media\/7460"}],"wp:attachment":[{"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/media?parent=7467"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/categories?post=7467"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spraysensors.tecnar.com\/fr\/wp-json\/wp\/v2\/tags?post=7467"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}